Home
Products:
Overview BRK DC DD DIM ENC FDB FLV MDR SP/DP SSR UNI
|
SP / DP
General Purpose Relay Modules

The SPST, SPST-DM, DPST, and DPDT modules feature electro-mechanical
relays, the time-proven "work horse" of power control. They offer reliable and
cost efficient switching solutions with air-gap isolation for a large variety of
applications. The SPST modules are the ultimate in cost efficient switching and employ a
industry-standard relay that performs billions of operations every day in systems all over
the world. They are intended for general purpose, light to normal duty applications, and
are also well suited as pilot relays for larger external relays and contactors. The
SPST-DM modules offer an excellent solution for normal to heavy-duty applications where
reliability and durability are major concerns. They utilize a dual make/break
configuration to provide a large number of operations and handle relatively large inrush
currents associated with incandescent lighting and inductive loads like transformers and
lamp ballast. The DPST and DPDT modules offer dual pole configurations of one of the most
commonly used relays in HVAC, industrial and process control. These versatile modules find
numerous applications in more complex control systems as well as in applications like
fountain and pool lighting where safety considerations require a positive disconnect of
two poles.
The SPST, SPST-DM, DPST, and DPDT modules, as the rest of the unique PWR Series, were
designed for exceptional reliability and durability under demanding circumstances. The PWR
Series is a dimming and power control system for distributed installation in environments
ranging from theme parks and theatres to sophisticated commercial, corporate, and public
buildings. It's modularity and extensive features facilitate an unmatched selection of
cost effective solutions to numerous control tasks in a wide variety of applications
including lighting control and energy management. The PWR Series provides unparalleled
versatility and scalability with a comprehensive range of controllers, dimmers, switching
modules, and enclosures with or without integral circuit breakers.
| Model |
Description |
Module
Spaces |
| SPST/1 |
1 x Form 1A, SPST-NO Relay Module |
1 |
| SPST/2 |
2 x Form 1A, SPST-NO Relay Module |
1 |
| SPST/3 |
3 x Form 1A, SPST-NO Relay Module |
1 |
| SPST-DM/1 |
1 x Form 1X, SPST-NO-DM Relay Module |
1 |
| SPST-DM/2 |
2 x Form 1X, SPST-NO-DM Relay Module |
1 |
| SPST-DM/2 |
3 x Form 1X, SPST-NO-DM Relay Module |
1 |
| DPST/1 |
1 x Form 2A, DPST-NO Relay Module |
1 |
| DPST/2 |
2 x Form 2A, DPST-NO Relay Module |
1 |
| DPST/3 |
3 x Form 2A, DPST-NO Relay Module |
1 |
| DPDT/1 |
1 x Form 2C, DPDT Relay Module |
1 |
| DPDT/2 |
2 x Form 2C, DPDT Relay Module |
1 |
Specifications
SPST, SPST-DM, DPST & DPDT
1. The switching modules shall be PWR Series SPST/1, SPST/2, SPST/3, SPSTDM/1,
SPST-DM/2, SPST-DM/3, DPST/1, DPST/2, DPST/3, DPDT/1 or DPDT/2 as required by the circuit
layout.
2. All modules shall employ industry standard general purpose electro-mechanical
relays. Solid-state, mercury relays, or devices not offering a dual make/break mechanism
for heavy duty applications shall not be acceptable.
3. The SPST modules shall provide a Form 1A, single pole, single throw, normally
open, (SPST-NO) contact arrangement. The SPST-DM modules shall provide a Form 1X, single
pole, single throw, normally open, dual make (SPST-NO-DM) contact arrangement. The DPST
modules shall provide a Form 2A, dual pole, single throw, normally open (DPST-NO) contact
arrangement. The DPDT modules shall provide a Form 2C, dual pole, dual throw (DPDT)
contact arrangement.
4. Relays shall be constructed with silver-cadmium oxide contact material and
minimum UL Class F insulation materials. All internal wiring shall be UL recognized for
minimum 125°C operating temperature.
5. Initial contact resistance shall not exceed 75mOhms at 1A 5VDC/12VAC.
6. Relays shall provide a typical mechanical life of at least 5 million
operations.
7. Operate and release time, including bounce, shall not exceed 15ms for the SPST
modules and 25ms for the SPSTDM, DPST, and DPDT modules.
8. The relay air-gap mechanism shall meet or exceed the requirements in UL1472.
9. The module load circuit surge and transient withstand capability shall meet
and exceed the minimum recommendations of ANSI C64.21-1991. Continuous breakdown voltage
between control terminals and load terminals shall be no less than 2500V.
10. Line and load terminals shall accept up to #8AWG wire. Control wiring shall
be provided by a 24" harness factory terminated in a 4 position keyed plug-in
connector.
11. The modules shall be UL listed for continuous operation at 100% of their
rating per NEC 1999 Article 210-20-a. Systems failing to meet this requirement shall not
be acceptable.
12. The modules including their wiring, termination points, mounting hardware,
enclosure and controller shall be UL and cUL listed as a complete assembly and for
Canadian installations comply with CSA Standard C22.2 #14-M91. UL recognized or listed
devices alone shall not be acceptable unless documentation is submitted to verify that the
entire assembly, including the controller and enclosure, has been tested and evaluated by
a Nationally Recognized Testing Laboratory (NRTL) and found to meet all the
herein-mentioned standards and requirements.
13. The modules shall be listed with the following minimum UL and cUL ratings per
pole at 40°C ambient temperature:
| SPST |
| General Purpose |
120 Vac, 30 A
277 Vac, 10 A |
| Resistive |
125 Vac, 30 A
277 Vac, 10 A |
| Tungsten |
120 Vac, 8.3 A |
| Ballast |
125 Vac, 20 A
277 Vac, 10 A |
| Motor |
125 Vac, 1 hp
240 Vac, 1 hp
277 Vac, 1 hp |
| SPST-DM, DPST, & DPDT NO Contacts |
| General Purpose |
277 Vac, 30 A |
| Resistive |
277 Vac, 30 A |
| Tungsten |
120 Vac, 10 A |
| Motor |
125 Vac, 1 hp
240 Vac, 3 hp
277 Vac, 2.5 hp |
| DPDT NC Contacts |
| General Purpose |
277 Vac, 3 A |
| Resistive |
277 Vac, 3 A |
| Motor |
125 Vac, 1/8 hp
240 Vac, 1/3 hp |
For a printable version of this page and other downloadable formats click here.